D3SL-T/RFID electromagnetic locking type
1.png

·Electromagnetic force locking 500N

·Adopt a small plane "electromagnetic" locking structure.

·Support 16 to 20 cascaded connections.

·Design of permanent magnet in matcher

·Small body, simple installation

·Full-angle eye-catching indicator light

·No abrasive powder will be produced.

·IP65/IP67 protection


D3SL-T/RFID Series Selection Table

Locking mode

deploy

model

Output mode

coded system

Electromagnetic locking

normalized form

D3SL-T-DB-N2

NPN

universal coding

D3SL-T-DB-N1

NPN

Unique coding

D3SL-T-DB-P2

PNP

universal coding

D3SL-T-DB-P1

PNP

Unique coding

Advanced type

D3SL-T-DG-N2

NPN

universal coding

D3SL-T-DG-N1

NPN

Unique coding

D3SL-T-DG-P2

PNP

universal coding

D3SL-T-DG-P1

PNP

Unique coding


Technical parameters of D3SL-T/RFID

type

Hinged door

small-sized

M12 connector

normalized form

High functional type

working distance

Sao(off-0n)

4mm

Sar(on-0ff)

4mm

Response time

Lock → release

155ms

Release → lock

155ms

Detection → Non-detection

20ms+2ms* (Number of cascaded connections -1)

Non-detection → detection

300ms+25ms* (Number of cascaded units -1)

Control output

(OSSD output)

Output mode

Transistor output "2

Maximum load current

150mA

Residual voltage (on)

Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

OFF voltage

Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

leakage current

Up to 0.5mA

Maximum load capacity

0.8uF

Load connection resistance

Max. 2.5 Euro

AUX output

(Non-safety system output)

Output mode

Transistor output

Maximum load current

50mA

Residual voltage (ON)

Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

external input

(Short-circuit current)

Safety input

About 1.5 max 2

Locking control input OSSD action switching input

About 2.5 mA

Reset /EDM input

About 5mA (high functional type only)

EDM select input

About 2.5 mA (high functional type only)

Power Supply 

Power supply voltage

24 VDC 10% including ripple (P-P)10% Class2

consumed power

<5W

protective circuit

Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

Environmental resistance

Enclosure protection grade

IP65/67(IEC60529)

Operating ambient temperature

20 degrees below zero to 55 degrees without freezing.

Storage ambient temperature

25 degrees below zero to 70 degrees without freezing.

Using ambient humidity

5% to 95%RH

Storage environment humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

Applicable standards

ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


Model description of safety switch

 1728548977520914.png 



hookup

Standard type (NPN, cascade)

Standard (PNP, cascade)

1719978292858022.png

Standard type (NPN, cascade)

1719978426648983.png

Standard (PNP, cascade)

1719978725470017.png

Functional (NPN, cascade)

Functional (PNP, cascade)

1719979076106539.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

High functional type (NPN, cascade)

1719979521976024.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

Functional (PNP, cascade)

1719979875434469.png

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

S: reset switch

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

*1. Make ?EDM and reset: wire as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch


Indication of indicator light

1719983442751425.png


Product ruler diagram

1719983681983392.png


Selection Method of Safety Switch D3SL-T/RFID Series

1728618489514684.png



Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 国产一级一级毛片 | 好吊视频一区二区三区四区 | ass刘涛色AV网站 | 国产精品无码久久久久久 | 四川少妇特级真人毛片免费 | 茄子这里有精品视频在线 | 久久亚洲精品国产 | 一区二区精品视频不卡 | 成人无码区免费AⅤ片向日葵视频 | 成人国产精品秘 在线看sm | 精品国产肉伦伦在线观看 | 蜜乳AV一区日韩不卡 | 西西444WWW无码视频男男 | 极品美女母乳大喷射电影在线播放 | 亚洲秘 无码一区二区三区电影 | 亚洲无码在线播放 | 全国Av按摩店免费在线观看 | 黄色免费在线视频 | 国产互换人妻XXXX69张雅丹 | 欧美成人影视在线观看 | 欧炎性爱XXXX | 无码福利日韩精品 | 91在线无码精品秘 入口男同 | 波多野结衣一级毛片 | 久久久精品人妻一区二区三区潮 | 国产精品三级久久久 | 国产精品探花一区二区三区 | 午夜 码在线观看 | 国产一区二区视频区视区 | 99视频偷窥在线精品国自产拍 | 直接看的免费黄色视频网站 | 成人性色生活片免费看爆迷你毛片 | 亚洲一区二区三区免费 | 国产高清一二三区 | 婷婷涩嫩草鲁丝久久午夜精品 | 欧美性猛交XXXX乱大交俱乐部 | 最好看的中文在线观看 | 欧美丰满熟妇AAAA片视频 | 噜噜WWWWXXXX无码| 一级毛片免费开放 | 亚洲在线一区二区精品 |